En hybridväxelriktare ersätter både regulator och växelriktare i ett system och kombinerar dom i samma produkt! Har man dessutom tillgång till ett elnät eller en generator kan man även koppla in och använda för att ladda batterierna när inte solinstålningen räcker till. (OBS: Skickar inte ut på elnätet)
|
Models |
HF2420S60-100 |
HF2430S60-100 |
|
AC mode |
||
|
Rated input voltage |
220/230Vac |
|
|
Input voltage range |
(170Vac~280Vac) ±2%;(90Vac-280Vac)±2% |
|
|
Frequency |
50Hz/ 60Hz (Auto detection) |
|
|
Frequency Range |
47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz); |
|
|
Overload/short circuit protection |
Circuit breaker |
|
|
Efficiency |
>95% |
|
|
Conversion time (bypass and inverter) |
10ms (typical) |
|
|
AC reverse protection |
Available |
|
|
Maximum bypass overload current |
30A |
|
|
Inverter mode |
||
|
Output voltage waveform |
Pure sine wave |
|
|
Rated output power (VA / W) |
3000 |
3000 |
|
Own consumption ON / Energy save mode |
50W |
25W |
|
Power factor |
1 |
|
|
Rated output voltage (Vac) |
230Vac |
|
|
Output voltage error |
±5% |
|
|
Output frequency range (Hz) |
50Hz ± 0.3Hz/60Hz ± 0.3Hz |
|
|
Efficiency |
>92% |
|
|
Overload protection |
(102% < load<125%) ±10%: report error and turn off the output after5 minutes; (125% < load < 150%) ± 10%: report error and turn off the output after 10 seconds; Load >150% ±10%: report error and turn off the output after 5 seconds; |
|
|
Peak power |
4000 |
6000 |
|
Loaded motor capability |
1HP |
2HP |
|
Output short circuit protection |
Circuit breaker |
|
|
Bypass breaker specifications |
30A |
|
|
Rated battery input voltage |
24V (Minimum starting voltage 22V) |
|
|
Battery voltage range |
(20.0Vdc~33Vdc ± 0.6Vdc (Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery settable on LCD screen) |
|
|
Power saving mode AC charging |
Load ≤25W |
|
|
Battery type |
Lead acid or lithium battery |
|
|
Maximum charge current |
60A |
80A |
|
Charge current error |
± 5Adc |
|
|
Charge voltage range |
18.0Vdc~33Vdc |
|
|
Short circuit protection |
Circuit breaker and blown fuse |
|
|
Circuit breaker specifications |
30A |
|
|
Overcharge protection |
Alarm and turn off charging after 1 minute |
|
|
PV charging |
||
|
Maximum PV open circuit voltage |
100Vdc |
|
|
PV operating voltage range |
30-100Vdc |
|
|
MPPT voltage range |
30-95Vdc |
|
|
Battery voltage range |
18-33Vdc |
|
|
Maximum output power |
1400W |
|
|
PV charging current range (can be set) |
0-60A |
|
|
Charging short circuit protection |
Blown fuse |
|
|
Wiring protection Certified specifications |
Reverse polarity protection |
|
|
Certification |
CE(IEC/EN62109-1,-2)、ROHS2.0 |
|
|
EMC certification level |
EN61000 |
|
|
Operating temperature range |
-15°C to 55°C |
|
|
Storage temperature range |
-25°C ~ 60°C |
|
|
Humidity range |
5% to 95% (Conformal coating protection) |
|
|
Noise |
≤60dB |
|
|
Heat dissipation |
Forced air cooling, variable speed of fan |
|
|
Communication interface |
USB/RS485(Bluetooth/WiFi/GPRS)/Dry node control |
|
|
Size (L*W*D) |
378mm*280mm*103mm |
|
|
Weight (kg) |
6.2 |
|